Alkalinity (Total) TNTplus Vial Test (25-400 mg/L CaCO₃), 25 Tests

Alkalinity (Total) TNTplus Vial Test (25-400 mg/L CaCO₃), 25 Tests

Product Number: TNT870

Available
Price: Contact Us
Talk to an Expert

Expert Alkalinity test made simple.

Alkalinity TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime.

For photometric determination of total alkalinity in drinking water, wastewater, and boiler water.

Traditional alkalinity measurement has involved time consuming titrations requiring expensive glassware and subjective end point determination by difficult to see color changes. With Alkalinity TNTplus reagents, simply add sample and included indicator to the vial, invert to mix, and insert into your Hach spectrophotometer! The Direct Read Technology will provide your Total Alkalinity result to the nearest mg/L! No more cleaning glassware, dealing with large amounts of waste, and worrying about human errors.

Upgrade from traditional titration based methods to TNTplus Alkalinity reagents today!

25 Total Alkalinity reagent vials per box.

Applications:

  • Aquaculture
  • Boiler Water
  • Cooling Water
  • Groundwater
  • Industrial Wastewater
  • Membrane Protection
  • Municipal Water
  • Potable Water
  • Pre-Treatment
  • Primary Treatment
  • QA/QC Lab
  • Recreation/Pool
  • Secondary Treatment
  • Source Water
  • Steam Cycle
  • Tertiary Treatment
  • Water Conditioning
  • Water Cycle
  • Water Reuse

Benefits

Easy and safe handling

The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.

No reagent blank necessary

The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!

Automatic method detection

The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware.

Documented shelf life and COA

New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Certificate of Analysis (COA) is available on RFID tag on the box.